CylinderZinc die cast, stainless steel 304 cap and dust shutter
HandleStainless steel 304, polished or zinc die cast, black texture powder coated
RollerGlass fibre reinforced polyamide (PA6GF30)
ShaftSteel, zinc plated or stainless steel 303
Dust cover, blackGlass fibre reinforced polyamide (PA6GF30)
Cast-in boltsSteel, black passivated
Rotating locking deviceStainless steel 303
BodyGlass fibre reinforced polyamide (PA6GF30)
Adjustable camZinc die cast, passivated
StandardsIP65, DIN EN 61373
Additional

Electronic interface

Power requirements 12VDC/2A or 24VDC/2A, lock/unlock by reverse polarity (impulse length 0,3-1,0 s).

Optional sensor output

Sensor 1 Handle unlocked – open circuit, handle locked – closed circuit (max 30VDC/500mA).

Sensor 2 Handle open – open circuit, handle closed – closed circuit (max 30VDC/500mA, total max 10W).

Opening rotation

Two- and three-point cams combined with adapter cannot be used with handles with clockwise or 180º rotation.

Using two- and three-point cams without adapter works with all opening rotations.

Protection internal electronics

The internal enclosure for the electronics inside the Vector T3 meets IP44 (tested with cable entry facing downwards).

Maximum tightening torque 2,2 Nm.

More information

  • Cylinder: Zinc die cast, stainless steel 304 cap and dust shutter
  • Handle: Stainless steel 304, polished or zinc die cast, black texture powder coated
  • Roller: Glass fibre reinforced polyamide (PA6GF30)
  • Shaft: Steel, zinc plated or stainless steel 303
  • Dust cover, black: Glass fibre reinforced polyamide (PA6GF30)
  • Cast-in bolts: Steel, black passivated
  • Rotating locking device: Stainless steel 303
  • Body: Glass fibre reinforced polyamide (PA6GF30)
  • Adjustable cam: Zinc die cast, passivated

  • Standards: IP65 DIN EN 61373
  • Additional:

    Electronic interface

    Power requirements 12VDC/2A or 24VDC/2A, lock/unlock by reverse polarity (impulse length 0,3-1,0 s).

    Optional sensor output

    Sensor 1 Handle unlocked – open circuit, handle locked – closed circuit (max 30VDC/500mA).

    Sensor 2 Handle open – open circuit, handle closed – closed circuit (max 30VDC/500mA, total max 10W).

    Opening rotation

    Two- and three-point cams combined with adapter cannot be used with handles with clockwise or 180º rotation.

    Using two- and three-point cams without adapter works with all opening rotations.

    Protection internal electronics

    The internal enclosure for the electronics inside the Vector T3 meets IP44 (tested with cable entry facing downwards).

    Maximum tightening torque 2,2 Nm.